Part Number Hot Search : 
DJ22A 743SURD 04E272D 1N4961 1N3342RB IU0505SA A760H LGU2A
Product Description
Full Text Search
 

To Download NCV7513A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 NCV7513A FLEXMOSt Hex Low-Side MOSFET Pre-Driver
The NCV7513A programmable six channel low-side MOSFET pre-driver is one of a family of FLEXMOSTM automotive grade products for driving logic-level MOSFETs. The product is controllable by a combination of serial SPI and parallel inputs. It features programmable fault management modes and allows power-limiting PWM operation with programmable refresh time. The device offers 3.3 V/5.0 V compatible inputs and the serial output driver can be powered from either 3.3 V or 5.0 V. Power-on reset provides controlled powerup and two enable inputs allow all outputs to be simultaneously disabled. Each channel independently monitors its external MOSFET's drain voltage for fault conditions. Shorted load fault detection thresholds are fully programmable using an externally programmed reference voltage and a combination of four discrete internal ratio values. The ratio values are SPI selectable and allow different detection thresholds for each group of three output channels. Fault information for each channel is 2-bit encoded by fault type and is available through SPI communication. Fault recovery operation for each channel is programmable and may be selected for latch-off or automatic retry. The FLEXMOS family of products offers application scalability through choice of external MOSFETs.
Features http://onsemi.com MARKING DIAGRAM
32 LEAD LQFP FT SUFFIX CASE 873A
NCV7513A AWLYYWWG
A WL YY WW G
= Assembly Location = Wafer Lot = Year = Work Week = Pb-Free Package
ORDERING INFORMATION
Device NCV7513AFTG Package LQFP (Pb-Free) Shipping 250 Units/Tray
* * * * * *
*
* * * *
16-Bit SPI with Frame Error Detection 3.3 V/5.0 V Compatible Parallel and Serial Control Inputs 3.3 V/5.0 V Compatible Serial Output Driver Two Enable Inputs Open-Drain Fault and Status Flags Programmable - Shorted Load Fault Detection Thresholds - Fault Recovery Mode - Fault Retry Timer - Flag Masking Load Diagnostics with Latched Unique Fault Type Data - Shorted Load - Open Load - Short to GND AEC Qualified PPAP Capable NCV Prefix for Automotive and Other Applications Requiring Site and Change Controls These are Pb-Free Devices*
NCV7513AFTR2G
LQFP 2000 Tape & Reel (Pb-Free)
For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specification Brochure, BRD8011/D.
Benefits
* Scalable to Load by Choice of External MOSFET
*For additional information on our Pb-Free strategy and soldering details, please download the ON Semiconductor Soldering and Mounting Techniques Reference Manual, SOLDERRM/D.
(c) Semiconductor Components Industries, LLC, 2009
March, 2009 - Rev. 1
1
Publication Order Number: NCV7513A/D
NCV7513A
IN5 IN4 IN3 IN2 IN1 IN0 ENA2 VCC2
NCV7513A
Hex MOSFET Pre-Driver
VCC1
POWER ON RESET & BIAS CHANNEL 0
FAULT DETECT VSS VCC2
DRN0
POR
ENA1
GATE SELECT FLAG MASK DISABLE MODE REFRESH/REF
ENA ENA VCC2 DRN 1 2 REF DISABLE PARALLEL SERIAL IREF ENA ENA VCC2 DRN 1 2 REF DISABLE PARALLEL SERIAL
DRIVER
GAT0
VSS
CHANNEL 1
DRN1
CSB SCLK SI VDD SO
VCC POR CSB SCLK SI
6
VSS
GAT1 DRN2
CHANNEL 2
16 BIT
SPI
IREF ENA ENA VCC2 DRN 1 2 REF DISABLE PARALLEL SERIAL
VSS
GAT2 DRN3
CHANNEL 3
DRIVER
SO ENA ENA VCC2 1 2 REF DISABLE PARALLEL SERIAL DRN 12
IREF
VSS
GAT3 DRN4
VSS
CHANNEL 4
FAULT BITS
FLTB
FAULT LOGIC & REFRESH TIMER
ENA1 ENA ENA VCC2 DRN 1 2 REF DISABLE PARALLEL SERIAL
IREF
VSS
GAT4 DRN5
CHANNEL 5
2
GND
CLOCK
ENA 1
IREF
VSS
GAT5 VSS
4
FLTREF
+
FAULT REFERENCE GENERATOR
CH 0-2 CH 3-5
DRN 0:5 MASK 0:5 POR
DRAIN FEEDBACK MONITOR
STAB
-
OA
Figure 1. Block Diagram
http://onsemi.com
2
NCV7513A
28W
28W
14W
M
+5V POWER-ON RESET
RX1 RFILT
+5V OR +3.3V
CB1
VCC1 FLTREF ENA1
VCC2 DRN0 GAT0 DRN1 GAT1 DRN2
RD2 NID9N05CL RD1 NID9N05CL RD0 NID9N05CL
RST
RX2
ENA2 IN0 IN1 IN2 IN3
HOST CONTROLLER
PARALLEL
NCV7513A
GAT2 DRN3 GAT3 DRN4 GAT4 DRN5 GAT5 VDD SO VSS
RD5 RD4 RD3
UNCLAMPED LOAD CB2 NID9N05CL NID9N05CL NID9N05CL
VLOAD
SPI
IN4 IN5 FLTB CSB SCLK
IRQ I/O
RFPU
SI STAB
RSPU
GND
Figure 2. Application Diagram
http://onsemi.com
3
14W
5W
NCV7513A
PIN FUNCTION DESCRIPTION
Symbol FLTREF DRN0 - DRN5 GAT0 - GAT5 ENA1, ENA2 IN0 - IN5 CSB SCLK SI SO STAB FLTB VCC1 GND VCC2 VDD VSS Description Analog Fault Detect Threshold: 5.0 V Compliant Analog Drain Feedback: Internally Clamped Analog Gate Drive: 5.0 V Compliant Digital Master Enable Inputs: 3.3 V/5.0 V (TTL) Compatible Digital Parallel Input: 3.3 V/5.0 V (TTL) Compatible Digital Chip Select Input: 3.3 V/5.0 V (TTL) Compatible Digital Shift Clock Input: 3.3 V/5.0 V (TTL) Compatible Digital Serial Data Input: 3.3 V/5.0 V (TTL) Compatible Digital Serial Data Output: 3.3 V/5.0 V Compliant Digital Open-Drain Output: 3.3 V/5.0 V Compliant Digital Open-Drain Output: 3.3 V/5.0 V Compliant Power Supply - Low Power Path Power Return - Low Power Path - Device Substrate Power Supply - Gate Drivers Power Supply - Serial Output Driver Power Return - VCC2, VDD, Drain Clamps
DRN2
DRN3
DRN4
DRN5
GAT2
GAT3
GAT4
24 23 22 21 20 19 18 17 GAT1 DRN1 GAT0 DRN0 VCC2 VCC1 FLTREF GND 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 16 15 14 VSS STAB VDD SO SI SCLK CSB FLTB
GAT5 13 12 11 10 9 ENA1
NCV7513A
IN0
IN1
IN2
IN3
IN4
IN5
Figure 3. 32 Pin LQFP Pinout (Top View)
http://onsemi.com
4
ENA2
NCV7513A
MAXIMUM RATINGS (Voltages are with respect to device substrate.)
Rating DC Supply (VCC1, VCC2, VDD) Difference Between VCC1 and VCC2 Difference Between GND (Substrate) and VSS Output Voltage (Any Output) Drain Feedback Clamp Voltage (Note 1) Drain Feedback Clamp Current (Note 1) Input Voltage (Any Input) Junction Temperature, TJ Storage Temperature, TSTG Peak Reflow Soldering Temperature: Lead-Free 60 to 150 seconds at 217C (Note 2) Value -0.3 to 6.5 "0.3 "0.3 -0.3 to 6.5 -0.3 to 40 10 -0.3 to 6.5 -40 to 150 -65 to 150 260 peak Unit V V V V V mA V C C C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability.
ATTRIBUTES
Characteristic ESD Capability Human Body Model Machine Model Moisture Sensitivity (Note 2) Package Thermal Resistance (Note 3) Junction-to-Ambient, RqJA Junction-to-Pin, RYJL Value w " 2.0 kV w " 200 V MSL3 86.0 C/W 58.5 C/W
1. An external series resistor must be connected between the MOSFET drain and the feedback input in the application. Total clamp power dissipation is limited by the maximum junction temperature, the application environment temperature, and the package thermal resistances. 2. For additional information, see or download ON Semiconductor's Soldering and Mounting Techniques Reference Manual, SOLDERRM/D, and Application Note AND8003/D. 3. Values represent still air steady-state thermal performance on a 4 layer (42 x 42 x 1.5 mm) PCB with 1 oz. copper on an FR4 substrate, using a minimum width signal trace pattern (384 mm2 trace area).
RECOMMENDED OPERATING CONDITIONS
Symbol VCC1 VCC2 VDD VIN High VIN Low TA Main Power Supply Voltage Gate Drivers Power Supply Voltage Serial Output Driver Power Supply Voltage Logic High Input Voltage Logic Low Input Voltage Ambient Still-Air Operating Temperature Parameter Min 4.75 VCC1 - 0.3 3.0 2.0 0 -40 Max 5.25 VCC1 + 0.3 VCC1 VCC1 0.8 125 Unit V V V V V C
http://onsemi.com
5
NCV7513A
ELECTRICAL CHARACTERISTICS (4.75 VvVCCXv5.25 V, VDD = VCCX, -40CvTJv125C, unless otherwise specified.) (Note 4)
Characteristic VCC1 Supply Operating Current - VCC1 = 5.25 V, VFLTREF = 1.0 V ENAX = 0 ENA1 = ENA2 = VCC1, VDRNX = 0 V, GATX drivers off ENA1 = ENA2 = VCC1, GATX drivers on VCC1 Rising - ENAX, INX, SI, SCLK, CSB ENAX, INX, SI, SCLK, CSB ENAX, INX, SI, SCLK, CSB CSB VIN = 0 V ENA2, INX, SI, SCLK, VIN = VCC1 ENA1 VDD = 3.3 V, ISINK = 5.0 mA VDD = 3.3 V, ISOURCE = 5.0 mA Output High or Low CSB = 3.3 V STAB Active, ISTAB = 1.25 mA VSTAB = VCC1 FLTB Active, IFLTB = 1.25 mA VFLTB = VCC1 VFLTREF = 0 V (Note 5) (Note 5) VCL IDRNX = 10 mA IDRNX = ICL(MAX) = 10 mA Register 2: R1 = 0, R0 = 0 or R4 = 0, R3 = 0 Register 2: R1 = 0, R0 = 1 or R4 = 0, R3 = 1 Register 2: R1 = 1, R0 = 0 or R4 = 1, R3 = 0 Register 2: R1 = 1, R0 = 1 or R4 = 1, R3 = 1 DRNX Input Leakage Current VCC1 = VCC2 = VDD = 5.0 V, ENAX = INX = 0 V, VDRNX = VCL(MIN) VCC1 = VCC2 = VDD = 0 V, ENAX = INX = 0 V, VDRNX = VCL(MIN) - - - 3.65 0.150 2.0 - 100 -25 - 100 - VDD - 0.25 - -10 - - - - -1.0 0 30 27 - 20 45 70 95 -1.0 2.80 3.10 2.80 4.20 0.385 - - 330 -10 10 150 0.11 VDD - 0.11 22 - 0.1 - 0.1 - - - - 32 33.6 25 50 75 100 - 5.0 5.0 5.0 4.60 - - 0.8 500 - 25 200 0.25 - - 10 0.25 10 0.25 10 - VCC1 - 2.0 - - 37 30 55 80 105 1.0 V V V V mV mA mA kW V V W mA V mA V mA mA V dB V % VFLTREF % VFLTREF % VFLTREF % VFLTREF mA mA Symbol Conditions Min Typ Max Unit
Power-On Reset Threshold Power-On Reset Hysteresis Digital I/O VIN High VIN Low VIN Hysteresis Input Pullup Current Input Pulldown Current Input Pulldown Resistance SO Low Voltage SO High Voltage SO Output Resistance SO Tri-State Leakage Current STAB Low Voltage STAB Leakage Current FLTB Low Voltage FLTB Leakage Current Fault Detection - GATX ON FLTREF Input Current FLTREF Input Linear Range FLTREF Op-amp VCC1 PSRR DRNX Clamp Voltage DRNX Shorted Load Threshold GATX Output High VFLTREF = 1.0 V
4. Designed to meet these characteristics over the stated voltage and temperature recommended operating ranges, though may not be 100% parametrically tested in production. 5. Guaranteed by design.
http://onsemi.com
6
NCV7513A
ELECTRICAL CHARACTERISTICS (continued) (4.75 VvVCCXv5.25 V, VDD = VCCX, -40CvTJv125C, unless otherwise
specified.) (Note 6) Characteristic Fault Detection - GATX OFF DRNX Diagnostic Current ISG IOL DRNX Fault Threshold Voltage DRNX Off State Bias Voltage Gate Driver Outputs GATX Output Resistance GATX High Output Current GATX Low Output Current Turn-On Propagation Delay Turn-Off Propagation Delay Output Rise Time tP(ON) tP(OFF) tR Output High or Low VGATX = 0 V VGATX = VCC2 INX to GATX (Figure 4) CSB to GATX (Figure 5) INX to GATX (Figure 4) CSB to GATX (Figure 5) 20% to 80% of VCC2, CLOAD = 400 pF (Figure 4, Note 5) Output Fall Time tF 80% to 20% of VCC2, CLOAD = 400 pF (Figure 4, Note 5) Fault Timers Channel Fault Blanking Timer tBL(ON) tBL(OFF) Channel Fault Filter Timer Global Fault Refresh Timer (Auto-retry Mode) Timer Clock SO Supply Voltage SCLK Clock Period Maximum Input Capacitance SCLK High Time SCLK Low Time Sl Setup Time Sl Hold Time VDD tFF tFR VDRNX = 5.0 V; INX rising to FLTB falling (Figure 6) VDRNX = 0 V; INX falling to FLTB falling (Figure 6) Figure 7 Register 2: Bit R2 = 0 or R5 = 0 Register 2: Bit R2 = 1 or R5 = 1 ENA1 = 1 3.3 V Interface 5.0 V Interface - Sl, SCLK (Note 7) SCLK = 2.0 V to 2.0 V SCLK = 0.8 V to 0.8 V Sl = 0.8 V/2.0 V to SCLK = 2.0 V (Note 7) SCLK = 2.0 V to Sl = 0.8 V/2.0 V (Note 7) 30 90 7.0 7.5 30 - 3.0 4.5 - - 125 125 25 25 45 120 12 10 40 500 3.3 5.0 250 - - - - - 60 150 17 12.5 50 - 3.6 5.5 - 12 - - - - ms ms ms ms ms kHz V V ns pF ns ns ns ns - - 1.40 ms 1.0 -5.25 1.9 - - - 1.80 - - - - - 2.5 -1.9 5.25 1.0 1.0 1.40 kW mA mA ms ms ms VSG VOL VCTR Short to GND Detection, VDRNX = 0.30 VCC1 Open Load Detection, VDRNX = 0.75 VCC1 Short to GND Detection Open Load Detection - -27 30 27 72 - -20 60 30 75 50 -10 80 33 78 - mA mA %VCC1 %VCC1 %VCC1 Symbol Conditions Min Typ Max Unit
Serial Peripheral Interface (Figure 9) Vccx = 5.0 V, VDD = 3.3 V, FSCLK = 4.0 MHz, CLOAD = 200 pF
6. Designed to meet these characteristics over the stated voltage and temperature recommended operating ranges, though may not be 100% parametrically tested in production. 7. Guaranteed by design.
http://onsemi.com
7
NCV7513A
ELECTRICAL CHARACTERISTICS (continued) (4.75 VvVCCXv5.25 V, VDD = VCCX, -40CvTJv125C, unless otherwise
specified.) (Note 8) Characteristic Symbol Conditions Min Typ Max Unit
Serial Peripheral Interface (continued) (Figure 9) Vccx = 5.0 V, VDD = 3.3 V, FSCLK = 4.0 MHz, CLOAD = 200 pF SO Rise Time SO Fall Time CSB Setup Time CSB Hold Time CSB to SO Time SO Delay Time Transfer Delay Time (20% VSO to 80% VDD) CLOAD = 200 pF (Note 9) (80% VSO to 20% VDD) CLOAD = 200 pF (Note 9) CSB = 0.8 V to SCLK = 2.0 V (Note 9) SCLK = 0.8 V to CSB = 2.0 V (Note 9) CSB = 0.8 V to SO Data Valid (Note 9) SCLK = 0.8 V to SO Data Valid (Note 9) CSB Rising Edge to Next Falling Edge (Note 9) - - 60 75 - - 1.0 25 - - - 65 65 - 50 50 - - 125 125 - ns ns ns ns ns ns ms
8. Designed to meet these characteristics over the stated voltage and temperature recommended operating ranges, though may not be 100% parametrically tested in production. 9. Guaranteed by design.
http://onsemi.com
8
NCV7513A
INX
50%
tP(OFF) GAT X tP(ON)
50% 80% 20%
tR
tF
Figure 4. Gate Driver Timing Diagram - Parallel Input
CSB
50%
GX tP(OFF) GAT X tP(ON)
Figure 5. Gate Driver Timing Diagram - Serial Input
50%
DRNX
INX
50%
tBL(ON) FLTB
50%
tBL(OFF)
50%
Figure 6. Blanking Timing Diagram
http://onsemi.com
9
NCV7513A
OPEN LOAD THRESHOLD
DRNX
SHORTED LOAD THRESHOLD
INX tFF FLTB
50%
tFF
50%
Figure 7. Filter Timing Diagram
GAT X
tBL(ON)
tFR
tFF
tFR
tBL(ON)
tFR
DRNX
SHORTED LOAD THRESHOLD (FLTREF)
INX
Figure 8. Fault Refresh Timing Diagram
CSB SETUP
TRANSFER DELAY
CSB
SI SETUP CSB HOLD
16
SCLK
1
SI HOLD
SI
CSB to SO VALID
MSB IN
BITS 14...1 SO DELAY
LSB IN
SO RISE,FALL
SO
MSB OUT
BITS 14...1
LSB OUT
SEE NOTE
80% VDD 20% VDD
Note: Not defined but usually MSB of data just received.
Figure 9. SPI Timing Diagram
http://onsemi.com
10
NCV7513A
DETAILED OPERATING DESCRIPTION General The NCV7513A is a six channel general purpose low-side pre-driver for controlling and protecting N-type logic level MOSFETs. While specifically designed for driving MOSFETs with resistive, inductive or lamp loads in automotive applications, the device is also suitable for industrial and commercial applications. Programmable fault detection and protection modes allow the NCV7513A to accommodate a wide range of external MOSFETs and loads, providing the user with flexible application solutions. Separate power supply pins are provided for low and high current paths to improve analog accuracy and digital signal integrity. ON Semiconductor's SMARTDISCRETES TM clamp MOSFETs, such as the NID9N05CL, are recommended when driving unclamped inductive loads. Power Up/Down Control The NCV7513A's powerup/down control prevents spurious output operation by monitoring the VCC1 power supply. An internal Power-On Reset (POR) circuit causes all GATX outputs to be held low until sufficient voltage is available to allow proper control of the device. All internal registers are initialized to their default states, fault data is cleared, and the open-drain fault (FLTB) and status (STAB) flags are disabled. When VCC1 exceeds the POR threshold, outputs and flags are enabled and the device is ready to accept input data. When VCC1 falls below the POR threshold during power down, flags are reset and disabled and all GATX outputs are driven and held low until VCC1 falls below about 0.7 V. SPI Communication The NCV7513A is a 16-bit SPI slave device. SPI communication between the host and the NCV7513A may either be parallel via individual CSB addressing or daisy-chained through other devices using a compatible SPI protocol. The active-low CSB chip select input has a pullup current source. The SI and SCLK inputs have pulldown current sources. The recommended idle state for SCLK is low. The tri-state SO line driver can be supplied with either 3.3 or 5.0 V and is powered via the device's VDD and VSS pins. The NCV7513A employs frame error detection that requires integer multiples of 16 SCLK cycles during each CSB high-low-high cycle (valid communication frame.) A frame error does not affect the flags. The CSB input controls SPI data transfer and initializes the selected device's frame error and fault reporting logic. The host initiates communication when a selected device's CSB pin goes low. Output (fault) data is simultaneously sent MSB first from the SO pin while input (command) data is received MSB first at the SI pin under synchronous control of the master's SCLK signal while CSB is held low (Figure 10). Fault data changes on the falling edge of SCLK and is guaranteed valid before the next rising edge of SCLK. Command data received must be valid before the rising edge of SCLK. When CSB goes low, frame error detection is initialized, latched fault data is transferred to the SPI, and the FLTB flag is disabled and reset if previously set. Data for faults detected while CSB is low are ignored but will be captured if still present after CSB goes high. If a valid frame has been received when CSB goes high, the last multiple of 16 bits received is decoded into command data, and FLTB is re-enabled. Latched (previous) fault data is cleared and current fault data is captured. The FLTB flag will be set if a fault is detected. If a frame error is detected when CSB goes high, new command data is ignored, and previous fault data remains latched and available for retrieval during the next valid frame. The FLTB flag will be set if a fault (not a frame error) is detected.
CSB
MSB LSB
2 3
SCLK
1
4 - 13
14
15
16
SI
X Z
B15 B15
B14 B14
B13 B13
B12 - B3 B12 - B3
B2 B2
B1 B1
B0 B0
UKN
X Z
SO
Note: X=Don't Care, Z=Tri-State, UKN=Unknown Data
Figure 10. SPI Communication Frame Format
http://onsemi.com
11
NCV7513A
Serial Data and Register Structure The 16-bit data sent by the NCV7513A is always the encoded 12-bit fault information, with the upper 4 bits forced to zero. The 16-bit data received is decoded into a 4-bit address and a 6-bit data word (see Figure 11). The upper four bits, beginning with the received MSB, are fully decoded to address one of four programmable registers and the lower six bits are decoded into data for the addressed register. Bit B15 must always be set to zero. The valid register addresses are shown in Table 1. Each register is next described in detail.
Table 1. Register Address Definitions
4-BIT ADDRESS B15 0 0 0 0 0 A2 0 0 0 0 1 A1 0 0 1 1 X A0 0 1 0 1 X 16-BIT OUTPUT DATA B15 0 B14 0 B13 0 B12 0 B11 D11 12-bit Fault Data B0 D0 D5 D4 6-BIT INPUT DATA D3 Gate Select Disable Mode Refresh & Reference Flag Mask Null D2 D1 D0
MSB
LSB
B15 B14 B13 B12 B11 B10 0 0 0 0 CH5
B9
B8
B7
B6
B5
B4
B3
B2
B1
B0
CH4
CH3
CH2
CH1
CH0
CHANNEL FAULT OUTPUT DATA REGISTER SELECT
MSB
COMMAND INPUT DATA
LSB
B15 B14 B13 B12 B11 B10 0 A2 A1 A0 X X
B9 X
B8 X
B7 X
B6 X
B5 D5
B4 D4
B3 D3
B2 D2
B1 D1
B0 D0
Figure 11. SPI Data Format
Gate Select - Register 0 Each GATX output is turned on/off by programming its respective GX bit (see Table 2). Setting a bit to 1 causes the selected GATX output to drive its external MOSFET's gate to VCC2 (ON). Setting a bit to 0 causes the selected GATX output to drive its external MOSFET's gate to VSS (OFF). Note that the actual state of the output depends on POR, ENAX and shorted load fault states as later defined by Equation 1. At powerup, each bit is set to 0 (all outputs OFF).
Table 2. Gate Select Register
A2 0 A1 0 A0 0 D5 G5 D4 G4 D3 G3 D2 G2 D1 G1 D0 G0
to 1 causes the selected GATX output to latch-off when a fault is detected. Setting a bit to 0 causes the selected GATX output to auto-retry when a fault is detected. At powerup, each bit is set to 0 (all outputs in auto-retry mode).
Table 3. Disable Mode Register
A2 0 A1 0 A0 1 D5 M5 D4 M4 D3 M3 D2 M2 D1 M1 D0 M0
0 = AUTO-RETRY 1 = LATCH OFF
0 = GATX OFF 1 = GATX ON
Disable Mode - Register 1 The disable mode for shorted load faults is controlled by each channel's respective MX bit (see Table 3). Setting a bit
Refresh and Reference - Register 2 Refresh time (auto-retry mode) and shorted load fault detection references are programmable in two groups of three channels. Refresh time and the fault reference for channels 5-3 is programmed by RX bits 5-3. Refresh time and the fault reference for channels 2-0 is programmed by RX bits 2-0 (see Table 4). At powerup, each bit is set to 0 (VFLT = 25% VFLTREF , tFR = 10 ms).
http://onsemi.com
12
NCV7513A
Table 4. Refresh and Reference Register A2 0 A1 1 A0 0 D5 R5 X X X X X X 0 1 D4 R4 CHANNELS 5-3 25% VFLTREF 50% VFLTREF 75% VFLTREF VFLTREF tFR = 10 ms tFR = 40 ms tFR = 10 ms tFR = 40 ms 0 0 1 1 X X X X 0 1 0 1 X X X X X X X X 0 1 X X D3 R3 D2 R2 D1 R1 CHANNELS 2-0 0 0 1 1 X X X X 0 1 0 1 X X X X D0 R0
Flag Mask - Register 3 The drain feedback from each channel's DRNX input is combined with the channel's KX mask bit (Table 5). When KX = 1, a channel's mask is cleared and its feedback to the FLTB and STAB flags is enabled. At powerup, each bit is set to 0 (all masks set).
Table 5. Flag Mask Register
A2 0 A1 1 A0 1 D5 K5 D4 K4 D3 K3 D2 K2 D1 K1 D0 K0
0 = MASK SET 1 = MASK CLEAR
The STAB flag is influenced when a mask bit changes CLRSET after one valid SPI frame. FLTB is influenced after two valid SPI frames. This is correct behavior for FLTB since, while a fault persists, the FLTB will be set when CSB goes LOHI at the end of an SPI frame. The mask instruction is decoded after CSB goes LOHI so FLTB will only reflect the mask bit change after the next SPI frame. Both FLTB and STAB require only one valid SPI frame when a mask bit changes SETCLR. Null Register - Register 4 Fault information is always returned when any register is addressed. The null register (Table 6) provides a way to read back fault information without regard to the content of DX.
Table 6. Null Register
A2 1 A1 X A0 X D5 X D4 X D3 X D2 X D1 X D0 X
Gate Driver Control and Enable Each GATX output may be turned on by either its respective parallel INX input or the internal GX (Gate Select) register bit via SPI communication. The device's common ENAX enable inputs can be used to implement global control functions, such as system reset, overvoltage or input override by a watchdog controller. Each parallel input and the ENA2 input have individual internal pulldown current sources. The ENA1 input has an internal pulldown resistor. Unused parallel inputs should be connected to GND and unused enable inputs should be connected to VCC1. Parallel input is recommended when low frequency (v2.0 kHz) PWM operation of the outputs is desired. ENA2 disables all GATX outputs when brought low. When ENA1 is brought low, all GATX outputs, the timer clock, and the flags are disabled. The fault and gate registers are cleared and the flags are reset. New serial GX data is ignored while ENA1 is low but other registers can be programmed. When both the ENA1 and ENA2 inputs are high, the outputs will reflect the current parallel or serial input states. This allows ENA1 to be used to perform a soft reset and ENA2 to be used to disable the GATX outputs during initialization of the NCV7513A. The INX input state and the GX register bit data are logically combined with the internal (active low) power-on reset signal (POR), the ENAX input states, and the shorted load state (SHRTX) to control the corresponding GATX output such that:
GATX + POR * ENA1 * ENA2 * SHRTx * (INx ) Gx)
(eq. 1)
http://onsemi.com
13
NCV7513A
The GATX state truth table is given in Table 7.
Table 7. Gate Driver Truth Table
POR 0 1 1 1 1 1 1 1 1 1 1 ENA1 X 0 0 1 1 1 1 1 10 1 1 ENA2 X 0 1 0 1 1 1 1 1 10 01 SHRTX X X X X 1 1 1 0 X X X INX X X X X 0 1 X X X X 0 GX X X X X 0 X 1 X 0 GX GX GATX L L L L L H H L L L GX
On-state faults will initiate MOSFET protection behavior, set the FLTB flag and the respective channel's DX bits in the device's fault latches. Off-state faults will simply set the FLTB flag and the channel's DX bits. Fault types are uniquely encoded in a 2-bit per channel format. Fault information for all channels simultaneously is retrieved by SPI read (Figure 11). Table 8 shows the fault-encoding scheme for channel 0. The remaining channels are identically encoded.
Table 8. Fault Data Encoding
CHANNEL 0 D1 0 0 1 1 D0 0 1 0 1 NO FAULT OPEN LOAD SHORT TO GND SHORTED LOAD STATUS
Gate Drivers The non-inverting GATX drivers are symmetrical resistive switches (1.80 kW typ.) to the VCC2 and VSS voltages. While the outputs are designed to provide symmetrical gate drive to an external MOSFET, load current switching symmetry is dependent on the characteristics of the external MOSFET and its load. Figure 12 shows the gate driver block diagram.
DX0 DX1 tFR R | R5 2 MX IN X GX ENA1 ENA2 POR
ENCODING LOGIC FILTER TIMER BLANKING TIMER FAULT DETECTION
50
DRNX
VSS VCC2 DRIVER
S LATCH OFF / AUTO RE-TRY _ EN R
SHRT X
1800
VSS
GAT X
Figure 12. Gate Driver Channel
Blanking and Filter Timers Blanking timers are used to allow drain feedback to stabilize after a channel is commanded to change states. Filter timers are used to suppress glitches while a channel is in a stable state. A turn-on blanking timer is started when a channel is commanded on. Drain feedback is sampled after tBL(ON). A turn-off blanking timer is started when a channel is commanded off. Drain feedback is sampled after tBL(OFF). A filter timer is started when a channel is in a stable state and a fault detection threshold associated with that state has been crossed. Drain feedback is sampled after tFF. Blanking timers for all channels are started when both ENA1 and ENA2 go high or when either ENAX goes high while the other is high. The blanking time for each channel depends on the commanded state when ENAX goes high. While each channel has independent blanking and filter timers, the parameters for the tBL(ON), tBL(OFF), and tFF times are the same for all channels. Shorted Load Detection An external reference voltage applied to the FLTREF input serves as a common reference for all channels (Figure 13). The FLTREF voltage must be within the range of 0 to VCC1-2.0 V and can be derived via a voltage divider between VCC1 and GND. Shorted load detection thresholds can be programmed via SPI in four 25% increments that are ratiometric to the applied FLTREF voltage. Separate thresholds can be selected for channels 0-2 and for channels 3-5 (Table 4).
Fault Diagnostics and Behavior Each channel has independent fault diagnostics and employs blanking and filter timers to suppress false faults. An external MOSFET is monitored for fault conditions by connecting its drain to a channel's DRNX feedback input through an external series resistor. When either ENA1 or ENA2 is low, diagnostics are disabled. When both ENA1 and ENA2 are high, diagnostics are enabled. Shorted load (or short to VLOAD) faults can be detected when a driver is on. Open load or short to GND faults can be detected when a driver is off.
http://onsemi.com
14
NCV7513A
A shorted load fault is detected when a channel's DRNX feedback is greater than its selected fault reference after either the turn-on blanking or the filter has timed out.
VCC1 RX1 RX2
FLTREF
0 - 3V
VCC1
CHANNELS 0-2
3 2 1 0
+
2X4 DECODER
-
OA
R 75% R 50% R 25% R
3 2 1 0
R1
R0
KELVIN
REGISTER 2 BITS R4 R3
2X4 DECODER CHANNELS 3-5
Figure 13. Shorted Load Reference Generator
Fault Recovery Refresh Time Refresh time for shorted load faults is SPI programmable to one of two values for channels 0-2 (register bit R2) and for channels 3-5 (register bit R5) via the Refresh and Reference register (Table 4). A global refresh timer with taps at nominally 10 ms and 40 ms is used for auto-retry timing. The first faulted channel triggers the timer and the full refresh period is guaranteed for that channel. An additional faulted channel may initially retry immediately after its turn-on blanking time, but subsequent retries will have the full refresh time period. If all channels in a group (e.g. channels 0-2) become faulted, they will become synchronized to the selected refresh period for that group. If all channels become faulted and are set for the same refresh time, all will become synchronized to the refresh period. Open Load and Short to GND Detection A window comparator with fixed references proportional to VCC1 along with a pair of bias currents is used to detect open load or short to GND faults when a channel is off. Each channel's DRNX feedback is compared to the references after either the turn-off blanking or the filter has timed out. Figure 14 shows the DRNX bias and fault detection zones. The diagnostics are disabled and the bias currents are turned off when ENAX is low. No fault is detected if the feedback voltage at DRNX is greater than the VOL open load reference. If the feedback is less than the VSG short to GND reference, a short to GND fault is detected. If the feedback is less than VOL and greater than VSG, an open load fault is detected.
I DRNX
Short to GND Open Load No Fault
Shorted Load Fault Recovery Shorted load fault disable mode for each channel is individually SPI programmable via the MX bits in the device's Disable Mode register (Table 3). When latch-off mode is selected the corresponding GATX output is turned off upon detection of a fault. Fault recovery is initiated by toggling (ONOFFON) the channel's respective INX parallel input, serial GX bit, or ENA2. When auto-retry mode is selected (default mode) the corresponding GATX output is turned off for the duration of the programmed fault refresh time (tFR) upon detection of a fault. The output is automatically turned back on (if still commanded on) when the refresh time ends. The channel's DRNX feedback is resampled after the turn-on blanking time. The output will automatically be turned off if a fault is again detected. This behavior will continue for as long as the channel is commanded on and the fault persists. In either mode, a fault may exist at turn-on or may occur some time afterward. To be detected, the fault must exist longer than either tBL(ON) at turn-on or longer than tFF some time after turn-on. The length of time that a MOSFET stays on during a shorted load fault is thus limited to either tBL(ON) or tFF. In auto-retry mode, a persistent shorted load fault will result in a low duty cycle (tFD [ tBL(ON)/tFR) for the affected channel and help prevent thermal failure of the channel's MOSFET. CAUTION - CONTINUOUS INPUT TOGGLING VIA INX, GX or ENA2 WILL OVERRIDE EITHER DISABLE MODE. Care should be taken to service a shorted load fault quickly when one has been detected.
I OL
0 -ISG VSG VCTR VOL VDRNX
Figure 14. DRNX Bias and Fault Detection Zones
Figure 15 shows the simplified detection circuitry. Bias currents ISG and IOL are applied to a bridge along with bias voltage VCTR (50% VCC1 typ.).
http://onsemi.com
15
NCV7513A
VCC1 I SG
A
CMP1
-
VOL
VLOAD
D3 D1
+ +
1600
DZ1
50
DRNX RDX +VOS
RLOAD VX RSG
B
CMP2
-
D4
D2
VSG VCTR + _ I OL
(VCL)
Figure 15. Short to GND/Open-Load Detection
When a channel is off and VLOAD and RLOAD are present, RSG is absent, and VDRNX >> VCTR, bias current IOL is supplied from VLOAD to ground through external resistors RLOAD and RDX, and through the internal 1650 W resistance and bridge diode D2. Bias current ISG is supplied from VCC1 to VCTR through D3. No fault is detected if the feedback voltage (VLOAD minus the total voltage drop caused by ISG and the resistance in the path) is greater than VOL. When either VLOAD or RLOAD and RSG are absent, the bridge will self-bias so that the voltage at DRNX will settle to about VCTR. An open load fault can be detected since the feedback is between VSG and VOL. Short to GND detection can tolerate up to a 1.0 V offset (VOS) between the NCV7513A's GND and the short. When RSG is present and VDRNX << VCTR, bias current ISG is supplied from VCC1 to VOS through D1, the internal 1650 W, and the external RDX and RSG resistances. Bias current IOL is supplied from VCTR to ground through D4. A "weak" short to GND can be detected when either VLOAD or RLOAD is absent and the feedback (VOS plus the total voltage rise caused by IOL and the resistance in the path) is less than VOL. When VLOAD and RLOAD are present, a voltage divider between VLOAD and VOS is formed by RLOAD and RSG. A "hard" short to GND may be detected in this case depending on the ratio of RLOAD and RSG and the values of RDX, VLOAD, and VOS. Note that the comparators see a voltage drop or rise due only to the 50 W internal resistance and the bias currents. This produces a small difference in the comparison to the actual feedback voltage at the DRNX input. Several equations for choosing RDX and for predicting open load or short to GND resistances, and a discussion of the dynamic behavior of the short to GND/open load diagnostic are provided in the Applications Information section of this data sheet.
Status Flag (STAB) The open-drain active-low status flag output can be used to provide a host controller with information about the state of a channel's DRNx feedback. Feedback from all channels is logically ORed to the flag (Figure 16). The STAB outputs from several devices can be wire-ORed to a common pullup resistor connected to the controller's 3.3 or 5.0 V VDD supply. When ENA1 is high, the drain feedback from a channel's DRNx input is compared to the VOL reference without regard to ENA2 or the commanded state of the channel's driver. The flag is reset and disabled when ENA1 is low or when all mask bits are set. See Table 9 for additional details. The flag is set (low) when the feedback voltage is less than VOL, and the channel's mask bit (Table 5) is cleared. The flag is reset (hi-Z) when the feedback voltage is greater than VOL, and the channel's mask bit is cleared.
KX VOL DRNX CMP1 OTHER CHANNELS D A 500 kHz POR Q CLR STAB
-
+
ENA1
Figure 16. STAB Flag Logic
Fault Flag (FLTB) The open-drain active-low fault flag output can be used to provide immediate fault notification to a host controller. Fault detection from all channels is logically ORed to the flag (Figure 17). The FLTB outputs from several devices can be wire-ORed to a common pullup resistor connected to the controller's 3.3 or 5.0 V VDD supply. The flag is set (low) when a channel detects any fault, the channel's mask bit (Table 5) is cleared, and both ENAx and CSB are high. The flag is reset (hi-Z) and disabled when either ENA1 or CSB is low. See Table 9 for additional details.
KX FAULT X ENA2 ENA1 POR CSB
(RESET DOMINANT)
OTHER CHANNELS S Q R
FLTB
Figure 17. FLTB Flag Logic
http://onsemi.com
16
NCV7513A
Fault Detection and Capture Each channel of the NCV7513A is capable of detecting shorted load faults when the channel is on, and short to ground or open load faults when the channel is off. Each fault type is uniquely encoded into two-bit per channel fault data. A drain feedback input for each channel compares the voltage at the drain of the channel's external MOSFET to several internal reference voltages. Separate detection references are used to distinguish the three fault types, and blanking and filter timers are used respectively to allow for output state transition settling and for glitch suppression. Fault diagnostics are disabled when either enable input is low. When both enable inputs are high, each channel's drain feedback input is continuously compared to references appropriate to the channel's input state to detect faults, but the comparison result is only latched at the end of either a blanking or filter timer event. Blanking timers for all channels are triggered when either enable input changes state from low to high while the other enable input is high, or when both enable inputs go high simultaneously. A single channel's blanking timer is triggered when its input state changes. If the comparison of the feedback to a reference indicates an abnormal condition when the blanking time ends, a fault has been detected and the fault data is latched into the channel's fault latch. A channel's filter timer is triggered when its drain feedback comparison state changes. If the change indicates an abnormal condition when the filter time ends, a fault has been detected and the fault data is latched into the channel's fault latch. Thus, a state change of the inputs (ENAX, INX or GX) or a state change of an individual channel's feedback (DRNX) comparison must occur for a timer to be triggered and a detected fault to be captured. Fault Capture, SPI Communication, and SPI Frame Error Detection The fault capture and frame error detection strategies of the NCV7513A combine to ensure that intermittent faults can be captured and identified, and that the device cannot be inadvertently reprogrammed by a communication error. The NCV7513A latches a fault when it is detected, and frame error detection will not allow any register to accept data if an invalid frame occurred. When a fault has been detected, the FLTB flag is set and fault data is latched into a channel's fault latch. The latch captures and holds the fault data and ignores subsequent fault data for that channel until a valid SPI frame occurs. Fault data from all channels is transferred from each channel's fault latch into the SPI shift register and the FLTB flag is reset when CSB goes low at the start of the SPI frame. Fault latches are cleared and re-armed when CSB goes high at the end of the SPI frame only if a valid frame has occurred; otherwise the latches retain the detected fault data until a valid frame occurs. The FLTB flag will be set if a fault is still present. Fault latches for all channels and the FLTB flag can also be cleared and re-armed by toggling ENA1 H-L-H. A full I/O truth table is given in Table 9. Fault Data Readback Examples Several examples are shown to illustrate fault detection, capture and SPI read-back of fault data for one channel. A normal SPI frame returns 16 bits of data but only the two bits of serial data for the single channel are shown for clarity.
* * * * * *
The examples assume: The NCV7513A is configured as in Figure 2 Both enable inputs are high The channel's flag mask bit is cleared Disable mode is set to auto-retry The parallel input commands the channel SPI frame is always valid
Shorted Load Detected Refer to Figure 18. The channel is commanded on when INX goes high. GATX goes high and the timers are started. At "A", the STAB flag is set as the DRNX feedback falls through the VOL threshold. A SPI frame sent soon after the INX command returns data indicating "no fault." The blanking time ends and the filter timer is triggered as DRNX rises through the FLTREF threshold. The STAB flag is reset as DRNX passes through the VOL threshold. DRNX is nearly at VLOAD when the filter time ends at "B". A shorted load fault is detected and captured by the fault latch, GATX goes low, the FLTB flag is set, and the auto-retry timer is started. An SPI frame sent soon after "B" returns data indicating "shorted load". The FLTB flag is reset when CSB goes low. At "C" when CSB goes high at the end of the frame, the fault latch is cleared and re-armed. Since INX and the DRNX feedback are unchanged, FLTB and the fault latch are set and the fault is recaptured. When the auto-retry timer ends at "D", GATX goes high and the blanking and filter timers are started. Since INX and DRNX are unchanged, GATX goes low when the blanking time ends at "E" and the auto-retry timer is started. Read-back data continues to indicate a "shorted load" and the FLTB flag continues to be set while the fault persists.
http://onsemi.com
17
NCV7513A
INx GATx DRNx
1 0 1 0
FAULT DETECTED
VLOAD VOL FLTREF 0
STAB
BLANK TIMER FILTER TIMER FAULT LATCH
1 0 1 0 1 0 1 0 1 0 1 0 1 0
A D B tBL(ON) tFF 00 11 C tFR tBL(ON) tFR
INTERNAL SIGNALS
E
11
11
11
11
CSB SO FLTB
00
11
11
11
11
11
Figure 18. Shorted Load Detected
http://onsemi.com
18
NCV7513A
Shorted Load Recovery Figure 19 is a continuation of Figure 18. INX is high when the auto-retry timer ends. GATX goes high and the blanking and filter timers are started. The fault is removed before the blanking timer ends, and DRNX starts to fall. As DRNX passes through the VOL threshold at "A", the STAB flag is set. DRNX continues to fall and settles below the FLTREF threshold. An SPI frame is sent during the blanking time and returns data indicating a "shorted load" fault. Although the fault is removed, updates to the fault latches are suppressed while a blanking or filter timer is active. The same fault is captured again and FLTB is set when CSB goes high. At "B" the blanking time ends and the channel's fault bits will
INx GATx DRNx
1 0 1 0
indicate "no fault" but because the latched data has not yet been read, the data remains unchanged. The SPI frame sent after the blanking time ends returns a "shorted load" fault because the previous frame occurred during the blanking time. Since the channel's fault bits indicate "no fault", FLTB is reset and the fault latch is updated at "C" when CSB goes high. If another SPI frame is sent before "D", the returned data will indicate "no fault". The channel is commanded off at "D". GATX goes low and the timers are started. DRNX starts to rise and the STAB flag is reset as DRNX passes through the VOL threshold. The SPI frame sent at "E" returns data indicating "no fault".
D
FAULT REMOVED
VLOAD VOL FLTREF 0
A
STAB
1 0
BLANK TIMER FILTER TIMER FAULT LATCH
1 0 1 0 1 0 1 0 1 0 1 0
B tFR tFF 11 11 11 tBL(ON)
INTERNAL SIGNALS
tBL(OFF) tFF 00
CSB SO FLTB
C 11 11 11 00
E
Figure 19. Shorted Load Recovery
http://onsemi.com
19
NCV7513A
Short to GND/Open Load Figure 20 illustrates turn-off with an open or high resistance load when some capacitance is present at DRNX. In the case of an open load, DRNX rises and settles to VCTR. In the case of a high resistance load, DRNX may continue to rise and may eventually settle to VLOAD. The channel is commanded off. GATX goes low and the timers are started. DRNX starts to rise and is below the VSG threshold when the blanking time ends at "A". A short to GND fault is detected and captured by the fault latch, and the FLTB flag is set. DRNX continues to rise and as it passes through the VSG threshold at "B", the filter timer is triggered. At the end of the filter time, the channel's fault bits will indicate an "open load" but because the latched data has not yet been read, the data remains unchanged. An SPI frame sent shortly after "B" returns data indicating "short to GND" and the fault latch is updated at "C" when CSB goes high. The next three frames sent after "C" return data indicating an "open load". The STAB flag is reset at "D" as DRNX passes through the VOL threshold. Note that the filter timer is not triggered as DRNX passes from a fault state to a good state. The channel's fault bits will indicate "no fault" but because the latched data has not yet been read, the data remains unchanged. The fault latch is updated at "E" when CSB goes high and the FLTB flag remains reset. The next SPI frame sent returns data indicating "no fault".
INx GATx DRNx
1 0 1 0
VLOAD VOL VCTR VSG 0
D A B C
STAB
BLANK TIMER FILTER TIMER FAULT LATCH
1 0 1 0 1 0 1 0 1 0 1 0 1 0
tBL(OFF) tFF 00 10 tFF 01
INTERNAL SIGNALS
E
01
01
00
CSB SO FLTB
00
10
01
01
01
00
Figure 20. Short to GND/Open Load
http://onsemi.com
20
NCV7513A
Table 9. I/O Truth Table
Inputs POR 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ENA1 X 0 1 10 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ENA2 X X 0 1 10 X 0 0 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CSB X X X X X X X X X X X 1 X X 10 01 1 X X 10 01 X 1 X X 10 01 1 X 1 X X 10 01 1 KX 0 X KX KX KX 0 1 1 10 01 1 1 10 01 1 1 1 10 01 1 1 1 1 10 01 1 1 1 1 1 10 01 1 1 1 INX X X X X X X X X X X 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 X X X X X X X GX 0 X GX 0 GX X X X X X 0 0 0 0 0 DRNX X X X X X X > VOL < VOL < VOL < VOL > VOL VSG VOL < VFLTREF VFLTREF VOL GATX L L L L L L L L L L L L L L L L L L L L L H L L L L L L H L L L L L L FLTB Z Z FLTB Z FLTB Z - - - - Z L L L LZ ZL L L L LZ ZL Z L L L LZ ZL L Z L L L LZ ZL L L L L LZ ZL L L L L LZ ZL L L Z L L LZ ZL L L Z STAB Z Z STAB Z STAB Z Z L LZ ZL Z L LZ Outputs* DX1DX0 00 00 DX1DX0 00 DX1DX0 - - - - - 00 01 01 01 01 01 10 10 10 10 10 00 11 COMMENT POR RESET ENA1 ENA2 ENA1 RESET ENA2 DISABLE FLAGS MASKED STAB RESET STAB SET STAB RESET STAB SET FLAGS RESET FLAGS SET STAB RESET STAB SET FLTB RESET FLTB SET FLAGS SET STAB RESET STAB SET FLTB RESET FLTB SET STAB SET FLAGS SET STAB RESET STAB SET FLTB RESET FLTB SET STAB RESET STAB SET FLAGS SET STAB RESET STAB SET FLTB RESET FLTB SET STAB RESET
0
0 0 0 0
0
X X
X X X X
X 1 1 1 1 1 1 1
11 11 11 11
11 00 11 11 11 11 11 11
* Output states after blanking and filter timers end and when channel is set to latch-off mode.
http://onsemi.com
21
NCV7513A
APPLICATION GUIDELINES General Unused DRNX inputs should be connected to VCC1 to prevent false open load faults. Unused parallel inputs should be connected to GND and unused enable inputs should be connected to VCC1. The mask bit for each unused channel should be `set' (see Table 5) to prevent activation of the flags and the user's software should be designed to ignore fault information for unused channels. For best shorted-load detection accuracy, the external MOSFET source terminals should be star-connected and the NCV7513A's GND pin, and the lower resistor in the fault reference voltage divider should be Kelvin connected to the star (see Figures 2 and 13). Consideration of auto-retry fault recovery behavior is necessary from a power dissipation viewpoint (for both the NCV7513A and the MOSFETs) and also from an EMI viewpoint. Driver slew rate and turn-on/off symmetry can be adjusted externally to the NCV7513A in each channel's gate circuit by the use of series resistors for slew control, or resistors and diodes for symmetry. Any benefit of EMI reduction by this method comes at the expense of increased switching losses in the MOSFETs. The channel fault blanking timers must be considered when choosing external components (MOSFETs, slew control resistors, etc.) to avoid false faults. Component choices must ensure that gate circuit charge/discharge times stay within the turn-on/turn-off blanking times. The NCV7513A does not have integral drain-gate flyback clamps. Clamp MOSFETs, such as ON Semiconductor's NID9N05CL, are recommended when driving unclamped inductive loads. This flexibility allows choice of MOSFET clamp voltages suitable to each application. DRNX Feedback Resistor Each DRNX feedback input has a clamp to keep the applied voltage below the breakdown voltage of the NCV7513A. An external series resistor (RDX) is required between each DRNX input and MOSFET drain. Channels may be clamped sequentially or simultaneously but total clamp power is limited to the maximum allowable junction temperature. To limit power in the DRNX input clamps and to ensure proper open load or short to GND detection, the RDX resistor must be dimensioned according to the following constraint equations:
RDX(MIN) + VPK-VCL(MIN) ICL(MAX) VSG-|VOS| |ISG|
(eq. 2)
RDX(MAX) +
(eq. 3)
where VPK is the peak transient drain voltage, VCL is the DRNX input clamp voltage, ICL(MAX) is the input clamp current, and VSG and ISG are the respective short to GND fault detection voltage and diagnostic current, and VOS is the allowable offset (1.0 V max) between the NCV7513A's GND and the short. Once RDX is chosen, the open load and short to GND detection resistances in the application can be predicted:
V -V ROL w LOAD OL * RDX IOL
(eq. 4)
RLOAD(VSG " VOS-|ISG|RDX) (eq. 5) RSG v VLOAD-VSG ) |ISG|(RDX ) RLOAD)
Using the data sheet values for VCL(MIN) = 27 V, ICL(MAX) = 10 mA, and choosing VPK = 55 V as an example, Equation 2 evaluates to 2.8 kW minimum. Choosing VCC1 = 5.0 V and using the typical data sheet values for VSG = 30%VCC1, ISG = 20 mA, and choosing VOS = 0, Equation 3 evaluates to 75 kW maximum. Selecting RDX = 6.8 kW "5%, VCC1 = 5.0 V, VLOAD = 12.0 V, VOS = 0 V, RLOAD = 555 W, and using the typical data sheet values for VOL, IOL, VSG, and ISG, Equation 4 predicts an open load detection resistance of 130.7 kW and Equation 5 predicts a short to GND detection resistance of 71.1 W. When RDX and the data sheet values are taken to their extremes, the open load detection range is 94.1 kW v ROL v 273.5 kW, and the short to GND detection range is 59.2 W v RSG v 84.4 W.
http://onsemi.com
22
NCV7513A
PACKAGE DIMENSIONS
32 LEAD LQFP CASE 873A-02 ISSUE C
A1
32
25
0.20 (0.008) AB T-U Z
1
-T- B B1
8
-U- V DETAIL Y
17
AE
BASE METAL
V1 AE
9
S1 S
0.20 (0.008) AC T-U Z
8X
M_
R
J
G -AB-
SEATING PLANE
DETAIL AD CE
SECTION AE-AE
-AC- 0.10 (0.004) AC W X DETAIL AD Q_
GAUGE PLANE
NOTES: 1. DIMENSIONING AND TOLERANCING PER ANSI Y14.5M, 1982. 2. CONTROLLING DIMENSION: MILLIMETER. 3. DATUM PLANE -AB- IS LOCATED AT BOTTOM OF LEAD AND IS COINCIDENT WITH THE LEAD WHERE THE LEAD EXITS THE PLASTIC BODY AT THE BOTTOM OF THE PARTING LINE. 4. DATUMS -T-, -U-, AND -Z- TO BE DETERMINED AT DATUM PLANE -AB-. 5. DIMENSIONS S AND V TO BE DETERMINED AT SEATING PLANE -AC-. 6. DIMENSIONS A AND B DO NOT INCLUDE MOLD PROTRUSION. ALLOWABLE PROTRUSION IS 0.250 (0.010) PER SIDE. DIMENSIONS A AND B DO INCLUDE MOLD MISMATCH AND ARE DETERMINED AT DATUM PLANE -AB-. 7. DIMENSION D DOES NOT INCLUDE DAMBAR PROTRUSION. DAMBAR PROTRUSION SHALL NOT CAUSE THE D DIMENSION TO EXCEED 0.520 (0.020). 8. MINIMUM SOLDER PLATE THICKNESS SHALL BE 0.0076 (0.0003). 9. EXACT SHAPE OF EACH CORNER MAY VARY FROM DEPICTION.
DIM A A1 B B1 C D E F G H J K M N P Q R S S1 V V1 W X
MILLIMETERS MIN MAX 7.000 BSC 3.500 BSC 7.000 BSC 3.500 BSC 1.400 1.600 0.300 0.450 1.350 1.450 0.300 0.400 0.800 BSC 0.050 0.150 0.090 0.200 0.450 0.750 12_ REF 0.090 0.160 0.400 BSC 1_ 5_ 0.150 0.250 9.000 BSC 4.500 BSC 9.000 BSC 4.500 BSC 0.200 REF 1.000 REF
INCHES MIN MAX 0.276 BSC 0.138 BSC 0.276 BSC 0.138 BSC 0.055 0.063 0.012 0.018 0.053 0.057 0.012 0.016 0.031 BSC 0.002 0.006 0.004 0.008 0.018 0.030 12_ REF 0.004 0.006 0.016 BSC 1_ 5_ 0.006 0.010 0.354 BSC 0.177 BSC 0.354 BSC 0.177 BSC 0.008 REF 0.039 REF
FLEXMOS and SMARTDISCRETES are trademarks of Semiconductor Components Industries, LLC (SCILLC).
ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. "Typical" parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including "Typicals" must be validated for each customer application by customer's technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner.
PUBLICATION ORDERING INFORMATION
LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303-675-2175 or 800-344-3860 Toll Free USA/Canada Fax: 303-675-2176 or 800-344-3867 Toll Free USA/Canada Email: orderlit@onsemi.com N. American Technical Support: 800-282-9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81-3-5773-3850 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your loca Sales Representative
0.250 (0.010)
H
K
http://onsemi.com
23
NCV7513A/D
0.20 (0.008)
-Z-
F
D
M
9
4X
DETAIL Y
EE EE EE EE
N
AC T-U Z
P
-T-, -U-, -Z-
A
4X


▲Up To Search▲   

 
Price & Availability of NCV7513A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X